BRAND | Berthold |
Product | LB480-2K-1C-12-01-000-L |
Description | Level measurement |
Internal code | FBR4531879 |
Custom code | 90222900 |
Technical specification | 54733-C3050 LB480-2K-1C-12-01-000-L Level Measurement UniSens LB 480, 2000 mm Power supply: 100 - 240 VAC, 50 - 60 Hz HART Master Detector, HART 7 compatible ATEX locations (Europe): II 2 G, II 2 D Locations NEC (USA)/CEC (Canada): Class I Zone 1, Zone 21 ATEX/IECEx/CEC Markings: Gas: Ex db eb IIC T6Gb Dust: Ex tb IIIC T95°C Db NEC Markings: Gas: AeX db eb IIC T6Gb Dust: AEx tb IIIC T95°C Db Ambient temp. T6: -40 °C... +65 °C T1 - T5: -40 °C... +80 °C Water cooling required above 60°C Signal output: 4... 20 mA, isolated, self-monitoring Protection: IP66, IP67, IP68, IP69K, Nema 4X, Nema 6 Current output: passive Digital output: open collector for signalling Error, min/max alarm, Det. -Temp., wheel. -Interf. Automatic Decay Compensation Self-monitoring Menu-guided setup via HART Radial cable entry M20 Licence Key 2 for Level Switch and Level Housing: stainless steel 1.4301 (304) |