(CLS-K-50 Compact amplifier)
Compact amplifier
CLS-K-63 Compact amplifier
(FAD-P-S-0,6-1200-67 ° by fiber optic transmitter S = D1, Empf.B1.2)
FAD T-A3.0-3,0-1500-67 ° through optical fiber
Adaptation board adjusted for ES1 type sensor, cable length 3m and non-ferromagnetic target material; (mounted in the DT3300 type controller
Adaptation board adjusted for ES2A type sensor, cable length 3m and non-ferromagnetic target material; (mounted in the DT3300 type controller)
Adaptation board adjusted for ES4 type sensor, cable length 3m and non-ferromagnetic target material; (mounted in the DT3300 type controller)
Adaptation board adjusted for EU8 type sensor, cable length 3m and non-ferromagnetic target material; (mounted in the DT3300 type controller)
Power supply, input 100-240 VAC, output +/-12 VDC and 5.2 VDC, with integral cable length 1.5 m and 7-pole female connector, for max. 4 multifunction controllers DT3300
Measuring range 0-1mm; mounting thread M8x1 with 3m (+/-15%) integral cable;
Shielded sensor Measuring range 1.0 mm mounting thread M8x1, sensor length 18 + 10 mm with 0.25 m integral coaxial cable (diameter 3 mm) and sealed triaxial female connector; max. operating temperature 150°C; housing material: stainless steel; compatible connecting cable: ECxx
Shielded sensor Measuring range 2 mm mounting thread M12x1, sensor length 25 mm with sealed triaxial female connector; pressure resistance (static): front 20bar and rearside splash water; max. operating temperature 150°C; housing material: stainless steel and plastics; compatible connecting cable: ECxx
Shielded sensor Measuring range 4 mm mounting thread M18x1, sensor length 25 mm with sealed triaxial female connector; pressure resistance (static): front 20bar and rearside splash water; max. operating temperature 150°C;housing material: stainless steel and plastics; compatible connecting cable: ECxx
Unshielded sensor Measuring range 8 mm mounting thread M24x1,5, sensor length 33,8 mm with sealed triaxial female connector; pressure resistance (static): front 20bar and rearside splash water; max. operating temperature 150°C; housing material: stainless steel and plastics; compatible connecting cable: ECxx
3 m long, with 8-pole female connector suitable to the signal conditioning controller, open ends for the connections
Supply and synchronisation cable, 0.3 m long with 7-pole male connector and 7-pole female connector suitable for multifunction controllers DT3300
cable
(+/-0.45m)
EC3 Sensor cable, 3 m (+/-0.45 m) long with sealed triaxial straightline male and 5-pole female connector suitable to DT3300 type controller
Micrometer calibration fixture range 0-2,5mm, 1 micrometer/division; adjustable offset (zero), for sensors with range < 2 mm;
cable TM-TIM PIF process interface, 1m cable, integr. electronics
sensor
Signal conditioning electronics in compact aluminium housing,power supply 9 ... 36 VDC or +/- 15 VDC,output: 0 ... 10 V and 4 ... 20 mA;adjusted for ferromagnetic targetmaterial (reference mild steel St37),adjusted for sensor ... (Serial Number on theelectronics label) and ... m interconnecting cable
Multifunction Controller Single-channel electronics for eddy current displacement sensors, with integrated LC-grafic display, aluminium housing, Output: 0-10 Volt and current output 4 - 20 mA, feeding +/-12 VDC / 100 mA and 5.2 VDC / 220 mA
thermo TIM 160 thermal imaging camera 48 ° optics Infrared Camera with USB 2.0 port Temperature ranges: -20 ° C - 100 ° C, 0 ° C - 250 ° C, 150 ° C - 900 ° C (Switchable) Spectral range: 7.5 -13 microns Optical resolution: 160x120 pixels Thermal Resolution: 0,1 ° C Lens Focal length: f = 4.5 mm / 48 ° lens Emissivity: 0,1 - 1,0 adjustable Ambient temperature: 0 ° C - 50 ° C Storage temperature: -40 ° C - 70 ° C Protection: IP67 Signal output: USB2.0 Refresh rate: 120Hz